MIL-P-45694(Ord)
TABLE I - CLASSIFICATION OF DEFECTS (Cont'd)
MINOR: AQL 4.0%
Req't
Par. QA.
Par..
Test Method
201.
Improper spin over of
Dwg FT689472
Visual
pivot
4.6.3
202. Illegibility of
3.7
Visual
marking
4.6.6
203. Improper identification
3.10
Visual
marking
204. Workmanship
3.4
4.6.7
Visual
TABLE II -
CLASSIFICATION OF DEFECTS
Use Inspection Level I, and Sampling Plan Table V of
Standard MIL-STD-105
CRITICAL: NONE DEFINED
QA. Par.
Test Method
MAJOR:
AQL 1.5%
Req't
Par.
101.
Operating
temperature
3.5.1
4.6.1.1
Standard Measure
Equipment(SME)
102. Storage temperature
3.5.2
4.6.1.2
SME
103. Evidence of damage
4.6.1.2
3.5.2
Visual-Tactile
or defects subse-
quent to storage
temperature test
4.6
Test
methods.
4.6.1
Environmental
testing.
4.6.1.1 Operating temperature.- The operating temperature test
shall be conducted in accordance with Procedure I of Specification
MIL-F-13926, except that the conditions specified in 3.5.1 shall
a p p l y . W h e n t h e r m a l s t a b i l i z a t i o n iS r e a c h e d a t t h e s p e c i f i e d
exposures, respectively, the plotting board shall be tested in
accordance with 4.6.2 through 4.6.5 to determine cornpliance with the
requirements of 3.5.1.