4.4.3 Failure of sample. Should any one item of a special sampling fall to meet the specified test requirements, acceptance of the represented inspection lot will be suspended by the Government until necessary corrections have been made by the contractor and resubmitted items have been approved in accordance with "Acceptance and Rejection" as specified in MIL-STD-105.
4.5 Inspection equipment. Except as otherwise provided for by the contract, the contractor shall supply and maintain inspection equipment in accordance with the applicable requirements of MIL-I-45607.
4.5.1 Government furnished inspection equipment. Where the contract provides for Government furnished test equipment, supply and maintenance of test equipment shall be in accordance with the applicable requirements specified in MIL-I-45607.
4.5.2 Contractor furnished inspection equipment.
4.5.2.1 Government desiqn. All inspection equipment specified by drawing number in specification or QAP forming a part of the contract shall be supplied by the contractor in accordance with technical data included in the Technical Data Package List (TDPL).
4.5.2.2 Contractor design. In the absence of Government inspection equipment design, the contractor shall design and supply inspection equipment compatible with the "Test Methods and Procedures" specified in 4.6 of this specification and with the component inspection procedures specified in "Examination" and "Test Facilities" requirements of MIL-F-13926. Since tolerance of test equipment is normally considered to be within 10% of the
product tolerance for which it is intended, this inherent error in the test equipment design must be considered as part of the prescribed product tolerance limit. Thus, concept, construction, materials, dimensions, and tolerance used in the design of test equipment shall be so selected and controlled as to insure that
the test equipment will reliably indicate. acceptability of a
product which does not exceed 90% of the prescribed tolerance limit, and permit positive rejection when non-conforming.
Construction shall be such as to facilitate routine calibration of test equipment.
4.5.2.3 Inspection equipment design requirements.
4.5.2.3.1 Temperature testinq. The volume of the test chamber shall conform to the test facilities requirements of
MIL-F-13926. The air temperature at the control sensor shall be
in accordance with the specified requirements within plus or minus
2.5°F (1.4°C). The temperature gradient across the
cross-sectional area occupied by the test item shall not exceed
8